Service Tools; Test Outputs - Bunn AutoPOD Technical Training Manual

Table of Contents

Advertisement

Troubleshooting and Repair
The AutoPOD™ brewer features on-board troubleshooting. Since all of the machine's components are controlled or
activated by the control board you can activate and test load components individually from the user interface to test
the inputs.
This allows you to listen to solenoid valves opening, observing the flow of water, switches operating, sensors operat-
ing, motor movement or test to see if a component is receiving voltage using a meter.
Memory is Locked Accessing Level 1 Programming
The program lockout switch is set to keep you from entering the program
menus and prohibit anyone from changing the settings. The menus can
be accessed to view the current settings. However, no changes will be
saved.
Enter the Level 1 Programming by pressing and holding the "Hidden
Switch" for 3 seconds or until display reads BREW LOCKOUT and then
release.
If the "Program Lockout Switch" is turned to the On position and you enter
Level 1 Programming, the following menus will display, reminding you the
memory is locked, and stop on the BREW LOCKOUT screen.
!!! CAUTION !!!
MEMORY IS LOCKED

Service Tools

To access SERVICE TOOLS enter Level 1 Pro-
gramming without lockout switch activated. Once
the BREW LOCKOUT menu is displayed, you will
navigate to the SERVICE TOOLS by pressing
and releasing the "Hidden Switch" consecutively.
If you pass the intended menu, you can step
backwards in the programming by pressing and
releasing the "Small Brew" switch while you are in
Level 1 Programming.
Select YES to enter into the SERVICE TOOLS
function.
SERVICE TOOLS ?
NO
YES
In the SERVICE TOOLS selection their are 3 screens available, by selecting YES, you will enter that test function, by
selecting NO you will move to the next test.

TEST OUTPUTS?

NO
YES
CONSTANT CHANGE
IS NOT POSSIBLE
TEST OUTPUTS will give you the option of turning On and Off the output voltage to the
load component individually. A voltmeter can be used across the load component to mea
sure the output voltage when commanded.
Bunn-O-Matic Corporation