Advertisement

INSTALLATION & OPERATING GUIDE
To ensure you have the latest revision of the Operating Manual, or to view the Illustrated Parts
Catalog, Programming Manual, or Service Manual, please visit the Bunn-O-Matic website, at
www.bunn.com. This is absolutely FREE, and the quickest way to obtain the latest catalog and
manual updates. For Technical Service, contact Bunn-O-Matic Corporation at 1-800-286-6070.
41167.0001A 08/10 ©2008 Bunn-O-Matic Corporation
BUNN-O-MATIC CORPORATION
POST OFFICE BOX 3227
SPRINGFIELD, ILLINOIS 62708-3227
PHONE: (217) 529-6601 FAX: (217) 529-6644

Advertisement

Table of Contents
loading

Summary of Contents for Bunn AutoPod

  • Page 1 To ensure you have the latest revision of the Operating Manual, or to view the Illustrated Parts Catalog, Programming Manual, or Service Manual, please visit the Bunn-O-Matic website, at www.bunn.com. This is absolutely FREE, and the quickest way to obtain the latest catalog and manual updates. For Technical Service, contact Bunn-O-Matic Corporation at 1-800-286-6070.
  • Page 2: Warranty

    SOLE OPTION AS SPECIFIED HEREIN, TO REPAIR, REPLACEMENT OR REFUND. In no event shall BUNN be liable for any other damage or loss, including, but not limited to, lost profits, lost sales, loss of use of equipment, claims of Buyer’s customers, cost of capital, cost of down time, cost of substitute equipment, facilities or services, or any other special, incidental or consequential damages.
  • Page 3: Table Of Contents

    DAMAGE, FIRE OR SHOCK HAZARD. #00656.0001 READ THE ENTIRE OPERATING MANUAL BEFORE USING THIS PRODUCT 00986.0000F 10/07 ©1994 Bunn-O-Matic Corporation #00986.0000 To reduce the risk of electric shock, Authorized service personnel only. do not remove or open cover. Disconnect power before servicing.
  • Page 4: Electrical Requirements

    ELECTRICAL REQUIREMENTS CAUTION - The brewer must be disconnected from the power source until specified in Initial Set-Up. Refer to Data Plate on the Brewer, and local/national electrical codes to determine circuit requirements. 120 VOLT Model 230 VOLT CE Model 230 VOLT UK Model Note: This electrical service consists of 2 current carrying conductors (L1 and Neutral) and a separate con-...
  • Page 5: Plumbing Requirements

    The water inlet fitting is .75-11.5 NH (HOSE THREAD). For convenience an elbow adaptor is provided to convert to a ¼˝ flare fitting. Bunn-O-Matic does not recommend the use of a reverse-osmosis or deionized water supply to this equipment.
  • Page 6: Initial Setup

    INITIAL SET-UP Place a large empty cup under the brew chamber. Brew water temperature is factory set at 200° F (93.3° C) Connect the brewer to the power source. Areas of high altitude will require lowering this tempera- Water will flow into the Hot Water tank and stop when ture to prevent boiling.
  • Page 7: Operation

    OPERATION COFFEE BREWING 1. Place cup under brew chamber FIG 8-1. (Slide booster out for small cups) FIG 8-3. 2. Press the OPEN/CLOSE switch to open pod door FIG 8-2. 3. Press fresh pod firmly down into pod holder FIG 8-3. 4.
  • Page 8: Cleaning

    1. Pull the driptray assembly straight towards you. sive, liquid detergent is recommended for cleaning 2. Pull the bin straight out and empty as required. all surfaces on Bunn-O-Matic equipment. 3. Seperate the parts as shown in Fig 8-4 and wash with mild, nonabrasive, liquid detergent.
  • Page 9: Tank Draining

    TANK DRAINING FACTORY BLOWOUT 1. Disconnect the power and water supply to brewer. Allow brewer to cool before proceeding. 2. Remove 2 screws that secure the top cover. Remove the cover. Place brewer next to a sink. 3. Disconnect the hose from (top) center hose barb of each tank. Connect a piece of ¼" ID hose (aproximately 12"...
  • Page 10: Programming

    PROGRAMMING SWITCHES HIDDEN SWITCH Press until display reads "BREW LOCKOUT" HIDDEN SWITCH Step forward through screens HOT WATER "YES" or (+) OPEN/CLOSE "NO" or (-) SMALL BREW (B) Step backwards through screens LARGE BREW (A) "DONE" Page 10 41167.1 051508...
  • Page 11 Sets the minimum temperature allowable to start a brew cycle. Range: (2° to 20° F) or (2° to 10° C) below the set temperature. Refer to the "PROGRAMMING MANUAL" at www.bunn. com for more advanced programming information. ENTER ASSET # This function allows the you to enter in an optional asset number.
  • Page 12 ADJUSTMENTS & OPTIONAL SETTINGS BREW LOCKOUT ? BREW TYPE A BREW OZ A: 8.0 DONE TEA DONE COFFEE DONE BREW OZ B: 6.0 BREW METER A: 2 BREW TYPE B TEA DONE COFFEE DONE BREW METER A: 2 ENTER SERVICE #? ENTER PASSWORD SET LANGUAGE ? UNITS...
  • Page 13 AIR PUMP POWER 4 DONE DONE BREW COUNT ## BREW COUNT ## CALIBRATE FLOW ? RESET NEXT CalibrateMaximum NUMBER OF EJECTS SEAL REPLACED ? NO H2O TIME? YES SINGLE DOUBLE SERVICE TOOLS ? FACTORY DEFAULTS AutoPOD BREWER VERSION xx.xx Page 13 41167.1 011609...
  • Page 14 SCHEMATIC WIRING DIAGRAM AUTOPOD MAGNET LEVEL PROBE HOT WATER TANK BREW TANK N.O. BIN OUT t° t° REED LIMIT LIMIT SWITCH THERMOSTAT THERMOSTAT TANK HEATER TANK HEATER RELAY WHI/RED WHI/RED AIR VENT SOLENOID WHI/BLU WHI/BLU INDEX SENSOR DISPLAY (SIG) (SIG)
  • Page 15 SCHEMATIC WIRING DIAGRAM AUTOPOD MAGNET HOT WATER TANK BREW TANK LEVEL PROBE N.O. t° t° BIN OUT LIMIT LIMIT THERMOSTAT THERMOSTAT REED LIMIT LIMIT SWITCH THERMOSTAT THERMOSTAT TANK HEATER TANK HEATER RELAY WHI/RED WHI/RED AIR VENT SOLENOID WHI/BLU WHI/BLU INDEX SENSOR...

Table of Contents