BMC
turn the LED on (blinking). If the LED is on, a button press or
IPMI Chassis Identify command will turn the LED off.

LEDs

The following table contains information on Status, ID and
Heartbeat LED's.
Table 4-1: Status LED, ID LED, and Heartbeat LED
LED
C
S
OLOR
Amber (Status
LED)
Power /
Status LED
Green
(Power LED
controlled by BIOS)
ID LED
Blue
Heartbeat
Green
LED
The following table contains information on Status LED when
amber blinking.
S
D
TATUS
ESCRIPTION
System Event
Blinking
(See following
Status LED table.)
Off
Normal status
On
Power On
Off
Power Off
Off
Normal status
Identify the system
Blinking
with interval
Solid ON
Identify the system
Off
BMC is not Ready
Blinking
BMC is Ready
Table 4-2: Status LED Activity
S
LED
TATUS
N
.
O
A
CTIVITY
1.
Temperature Sensor
2
Fan Sensors
3
Voltage Sensors
4
Power Supply
5.
Processor
6
Event Logging Disable
7
Post Error
8
Memory
9.
PCIe Bus
10
BMC Watchdog
4-2
F
P
U
I
RONT
ANEL
SER
NTERFACE
D
ESCRIPTION
Non-critical / critical event asserted
Non-critical / critical event asserted
State asserted
State asserted
Thermal trip
SEL almost full
SEL full
System firmware error
Correctable EEC error
Uncorrectable ECC error
Correctable ECC error logging
limit reached
Bus correctable error
Bus uncorrectable error
Bus fatal error
Timer expired
Hard Reset
Power Down
Power cycle