(e)
Out of range:
• Upon receipt of this command, data beyond the left/right margin will be dumped.
(f)
Additional details:
• The data in print buffer is printed if the range on left margin side (reverse) from
current position is selected.
• Score, if the score mode is set, is added if the range on right margin side (forward)
from current position is selected.
10)
Left margin set
(a)
Code: ESC I n
(b)
Compatibility: EPSON LQ
(c)
Function:
Left margin is set at (n) characters from printhead home position.
(d)
Range:
• n = 0 — 255
Name
PICA/PROPORTIONAL
ELITE
COMPRESSED
COMPRESSED ELITE
COMPRESSED Prop
(e)
Out of range:
If n exceeds the maximum value, this command will be ignored.
(f)
Additional details:
• The left margin is set as an absolute position according to the current character
pitch. Changes in character pitch do not change the margin position.
• The print buffer will be cleared.
• Maximum difference of left margin and right margin values is 2 characters for 5
CPI.
(g)
Related functions:
• Right margin set—ESC.Q.n.
40959201TX Rev.1
Pitch
ML380 Turbo
10
0 — 70
12
0 — 84
15
0 — 105
17.1
0 — 119
20
0 — 140
0 — 140
ML381 Turbo
0 — 126
0 — 151
0 — 189
0 — 215
0 — 252
0 — 252