Limitations for SPARC64 VII Processors

Caution – You must complete the upgrades to the XCP firmware and to Solaris OS
before inserting the CPU/memory board unit of SPARC 64 VII processors into the
chassis.

Notes on Active Directory

While Active Directory is enabled, when you attempt to login to XSCF via the
telnet, you might fail to login due to timeout of the query to secondary alternated
server or later.
If the specified timeout is too brief for the configuration, the login process or
retrieval of user privilege settings could fail. In such case, specify larger value for
the timeout and then execute again.

Notes on LDAP/SSL

If the specified timeout is too brief for the configuration, the login process or
retrieval of user privilege settings could fail. In such case, specify larger value for the
timeout and try again.

Notes on Airflow Indicator

The amount of exhaust air might not be indicated correctly in the MIB
information, in the showenvironment air command output, and on the XSCF
Web in the following cases; and you should wait for one minute and check the
value again.
The figures on the airflow indicator represent the volume of air exhausted from
the server. The figures of peripheral devices are not included.
6
SPARC Enterprise M8000/M9000 Servers Product Notes for XCP Version 1092 • April 2010
During the server powering on or powering off, or for a while after the power-
on or power-off complete
During the active replacement of power supply unit, or for a while after the
active replacement complete