Note: See "System" on page 110 to determine which components should be replaced by a field service technician.
Error code/symptom
604 (Diskette drive error)
662 (Diskette drive configuration error)
962 (Parallel port error)
11XX (System board serial port 1 or 2
error)
1762 (Hard drive configuration error, IDE
only.)
178X (Hard drive error, IDE only.)
1800 (No more hardware interrupt
available for PCI adapter.)
1801 (No more ROM space available for
PIC adapter.)
1962 (Drive does not contain a valid boot
sector)
5962 (IDE CD-ROM drive configuration
error)
8603 (Pointing-device error)
FRU/action
1. Run the Configuration/Setup Utility program and diagnostics.
2. Diskette drive.
3. Drive cable.
4. System board.
1. Run the Configuration/Setup Utility program and diagnostics.
2. Diskette drive.
3. Drive cable.
4. System board.
1. Run the Configuration/Setup Utility program.
2. System board.
1. Run the Configuration/Setup Utility program.
2. System board.
1. Hard disk drive.
2. Hard disk cables.
3. Run the Configuration/Setup Utility program.
4. System board.
1. Hard disk cables.
2. Hard disk adapter.
3. Hard disk drive.
4. System board.
1. Run the Configuration/Setup Utility program.
2. Remove adapter.
1. Run the Configuration/Setup Utility program.
2. Remove adapter.
3. Disable the adapter BIOs and run the Configuration/Setup Utility
program.
1. Verify that a startable operating system is installed.
2. Run diagnostics.
3. Hard disk drive.
4. SCSI backplane.
5. Cable.
6. System board.
1. Run the Configuration/Setup Utility program.
2. CD-ROM drive.
3. CD-ROM power cable.
4. IDE cable.
5. System board.
6. Battery.
1. Pointing device.
2. System board