IBM xSeries 205 Type 8480 Hardware Maintenance Manual And Troubleshooting Manual page 100

Hide thumbs Also See for xSeries 205 Type 8480:
Table of Contents

Advertisement

Note: See "System" on page 110 to determine which components should be replaced by a field service technician.
Error code/symptom
015-XXX-001 (USB interface not found,
board damaged)
015-XXX-015 (Failed USB external
loopback test.)
015-XXX-198 (USB device connected
during USB test.)
020-XXX-000 (Failed PCI interface test.)
020-XXX-001 (Failed hot-swap slot 1 PCI
latch test.)
020-XXX-002 (Failed Hot-swap slot 2 PCI
latch test.)
020-XXX-003 (Failed hot-swap slot 3 PCI
latch test.)
020-XXX-004 (Failed hot-swap slot 4 PCI
latch test.)
030-XXX-000 (Failed internal SCSI
interface test.)
035-XXX-099
035-XXX-S99 (Failed RAID test on PCI slot
S. S = number of failing PCI slot. Check
System Error Log before replacing a FRU.)
035-XXX-SNN (Check System Error Log
before replacing a FRU. s = number of
failing PCI slot, nn = SCSI ID of failing fixed
disk.)
035-253-S99 (RAID adapter initialization
failure.)
075-XXX-000 (Failed power supply test.)
089-XXX-001 (Failed microprocessor test.)
089-XXX-002 (Failed optional
microprocessor test.)
90
IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
FRU/action
1. System board.
1. Make sure the parallel port is not disabled.
2. Run the USB external loopback test again.
3. System board.
1. Remove USB devices from USB1 and USB2.
2. Run the USB external loopback test again.
3. System board.
v System board.
1. PCI hot-swap latch assembly
2. System board.
1. PCI hot-swap latch assembly.
2. System board.
1. PCI hot-swap latch assembly.
2. System board.
1. PCI hot-swap latch assembly.
2. System board.
v System board
1. No adapters were found.
2. If adapter is installed re-check connection.
1. Adapter.
2. SCSI backplane.
3. Cable.
v Hard disk drive with SCSI ID nnon RAID adapter in PCI slot s.
1. ServeRAID adapter in slot s is not configured properly. Obtain
the basic and extended configuration status and see the ServeRAID
Hardware Maintenance Manual for more information.
2. Cable.
3. SCSI backplane.
4. Adapter.
v Power supply
1. VRM 1 for microprocessor 1
2. Microprocessor 1
1. VRM 2 for optional microprocessor 2.
2. Optional microprocessor 2