Note: See "System" on page 110 to determine which components should be replaced by a field service technician.
Error code/symptom
166-342-000 System Management: Failed
(ASM adapter BIST indicate failed tests.)
166-400-000 System Management: Failed
(ISMP self test result failed tests: x where x
= Flash, RAM, or ROM.)
180-XXX-000 (Diagnostics LED failure.)
180-XXX-001 (Failed front LED panel test.)
180-XXX-002 (Failed diagnostics LED panel
test.)
180-361-003 (Failed fan LED test.)
180-XXX-003 (Failed system board LED
test.)
180-XXX-005 (Failed SCSI backplane LED
test.)
201-XXX-0NN (Failed memory test.)
201-XXX-999 (Multiple DIMM failure, see
error text.)
202-XXX-001 (Failed system cache test.)
202-XXX-002 (Failed system cache test.)
206-XXX-000 (Failed diskette drive test.)
215-XXX-000 (Failed IDE CD-ROM drive
test.)
217-198-XXX (Could not establish drive
parameters.)
217-XXX-000 (Failed BIOS hard disk test)
Note: If RAID is configured, the hard disk
number refers to the RAID logical array.
92
IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
FRU/action
1. Ensure the latest firmware levels for Remote Supervisor
Adapter and BIOS.
2. Disconnect all server and option power cords from server, wait 30
seconds, reconnect, and retry.
3. Remote Supervisor Adapter.
1. Reflash or update firmware for ISMP.
2. System board.
v Run diagnostics panel LED test for the failing LED.
1. Operator information panel.
2. System board.
1. Diagnostics panel.
2. System board.
1. Fan.
2. System board.
v System board.
1. SCSI backplane.
2. SCSI backplane cable.
3. System board.
1. DIMM Location slots 1-6 where nn = DIMM location.
Note: nn 1=DIMM 1; 2=DIMM 2; 3=DIMM 3; 4=DIMM 4; 5=DIMM
5; 6=DIMM 6.
2. System board.
1. See error text for failing DIMMs.
2. System board.
1. VRM 1.
2. Microprocessor 1.
1. VRM 2.
2. Microprocessor 2.
1. Cable.
2. Diskette drive.
3. System board.
1. CD-ROM drive cables.
2. CD-ROM drive.
3. System board.
1. Check cable and termination.
2. SCSI backplane.
3. Hard disk.
v Hard disk 1