E800; E802 - Canon NP6251 Service Manual

Hide thumbs Also See for NP6251:
Table of Contents

Advertisement

CHAPTER 11 TROUBLESHOOTING

28. E800

Cause
Step
Malfunction
1
J716
2
Power switch
3
(SW1)
DC controller
PCB

29. E802

Cause
Step
Malfunction
1
DC controller
2
PCB
Power supply
unit
11-98
COPYRIGHT © 1997 CANON INC.
Download service manual and resetter printer at http://printer1.blogspot.com
Checks
Turn off and then on the power
switch. Is the problem corrected?
Is the relay connector J716 under
the power switch (SW1)
connected securely?
Set the meter to the × 1Ω range.
Disconnect the relay connector
J716, and connect the probe of
the meter to the connector
terminal on the power switch side.
Is the voltage about 30Ω?
Checks
Turn off and on the power switch.
Is the problem corrected?
Replace the DC controller PCB. Is
the problem corrected?
CANON NP6350/NP6251 REV. 0 JULY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)
YES/NO
Action
YES
End.
NO
Connect it securely.
NO
Replace the power
switch (SW1).
YES
Check the wiring from
the DC controller PCB to
the power switch (SW1);
if normal, replace the DC
controller PCB.
YES/NO
Action
YES
End.
YES
End.
NO
Check the wiring and
electrical continuity from
the DC controller to the
power switch (SW1); if
normal, replace the DC
controller PCB.