Specifications - Follett C125A Installation, Operation And Service Manual

12 series ice and water dispensers
Table of Contents

Advertisement

16"
(407mm)
Dispenser front view
Electrical specifications
115V, 60Hz, 1 phase, 13.0 amps. Connect to 20 amp circuit, fuse or breaker.
Note: It is preferred that circuit be protected by a GFCI.
Furnished with 6 ft (1.8m) power cord with 5-20 plug
Ambient specifications
Air temp
100°F/38°C Max.
Water temp
90°F/32°C Max.
Water pressure
70 P.S.I. Max.
Plumbing specifications
C125A
Dispenser drain
3/4" FPT
Water inlet
3/8" FPT
Note:
Water shut-off recommended within 10 feet (3m) of dispenser. Drain to be hard-piped and insulated.
Maintain at least 1/4" per foot (6mm per 30.4cm run) of slope.
Ventilation clearances
6" (153mm) on right side of dispenser, 12" (305mm) at top
Do not block right side air intake or top air exhaust.
!
Dry weight
175 lbs (79.4kg)

Specifications

22.5"
(572mm)
Air
intake
4"
18"
(102mm)
(458mm)
23.6"
(600mm)
Dispenser side view
50°F/10°C Min. (Best performance below 80˚F/27˚C)
40°F/4°C Min. (Best performance below 70˚F/21˚C)
10 P.S.I. Min.
H125A
3/4" FPT
3/8" FPT
5
air exhaust
32.5"
(826mm)
air
intake
power cord
Dispenser rear view
3/8" FPT
water inlet
3/4" FPT drain