Refrigeration System Data And Requirements - Follett C125A Installation, Operation And Service Manual

12 series ice and water dispensers
Table of Contents

Advertisement

Refrigeration system
Important:
All service on refrigeration system must be performed in accordance with all federal, state and
local laws that pertain to the use of refrigerants. It is the responsibility of the technician to
ensure that these requirements are met.
Model
C125A, H125A (air-cooled)
Recharging of unit at other than factory specifications will void icemaker
!
warranty.
Refrigerant replacement requirements
1. Non-contaminated refrigerant removed from any Follett refrigeration system can be recycled and returned to
the same system after completing repairs. Recycled refrigerant must be stored in a clean, approved storage
container. If additional refrigerant is required, virgin or reclaimed refrigerant that meets ARI standard 700-88
must be used.
2. In the event of system contamination (for example, a compressor burn out, refrigerant leak, presence of non-
condensibles or moisture), the system must be repaired, evacuated and recharged using virgin or reclaimed
refrigerant that meets ARI standard 700-88.
3. Follett Corporation does not approve of recovered refrigerants. Improper refrigeration servicing procedures
will void the factory warranty.
Evacuation
Evacuate the system to a level of 50 microns. When the 50 micron level is reached, shut the vacuum pump down.
Allow the system to sit for approximately 30 seconds. During this period the system should not rise above 1000
microns. If the system rises above 1000 microns, evacuate the system again. If the system rises above 1000
microns for a second time, check the system for leaks.
Ambients
Air Temperature 1
Water Temperature 2
1 Ambient air temperature is measured at the air-cooled condenser coil inlet.
2 Ambient water temperature is measured in the icemaker float reservoir.
R22 icemaker charge specifications
Charge
24 oz
Minimum
50˚F/10˚C
40˚F/4.4˚C
23
Refrigerant type
R22
Maximum
100˚F/37.8˚C
90˚F/32.2˚C

Advertisement

Table of Contents
loading

This manual is also suitable for:

H125a

Table of Contents