Download Print this page

Welcome To Follett; Before You Begin; Important Cautions; Electrical Specifications - Follett U150 Operation, Service And Parts Manual

U150 series ice dispensers

Advertisement

Welcome to Follett

Follett ice dispensers enjoy a well-deserved reputation for excellent performance, long-term reliability and
outstanding after-the-sale support. To ensure that this dispenser delivers that same degree of service, we ask
that you take a moment to review this manual before using the dispenser. Should you have any questions or
require technical help at any point, please call our technical service group toll free at (800)523-9361 or
(610)252-7301.

Before you begin

Check your paperwork to determine which model you have. Following is an explanation of the different model
numbers in the U150 series.
U150BR5A

Important cautions

• Storage area of dispenser contains mechanical, moving parts. Keep hands and arms clear of
this area at all times. If access to this area is required, power to unit must be disconnected first.
• Follett manual load units can accommodate most cube/cubelet ices up to 1" square, or Follett
compressed nugget ice. Crushed, flake, bagged, nugget or congealed ice cannot be used. Use of
these ices can jam dispenser and void warranty. Separate any "waffle-like" sections of cubes
before adding to dispenser. If you have any questions concerning your ice type, please call
Follett's customer service group toll free at (800) 523-9361 or (888) 2-FOLLETT or (610) 252-7301.
• Follett recommends use of an activated carbon filter for units equipped with icemakers
• Ice is slippery. Maintain counters and floors around dispenser in a clean and ice-free condition.
• Ice is food. Follow recommended cleaning instructions to maintain cleanliness of delivered ice.

Electrical specifications

Standard electrical - 115V, 60Hz, 1 phase
Separate circuit and disconnects required for each icemaker and
dispenser. Max. fuse size 20 amps per circuit
Manual load models
U150N – dispenser 2.4 amps
U150 – dispenser 2.4 amps
U150B – dispenser 4.4 amps
Models with R4A/W Icemaker
U150R4A/W, U150NR4A/W – 13.4 amps
U150BR4A/W – 15.4 amps
U150R8A/W, U150NR8A/W – 24.4 amps
U150BR8A/W – 26.4 amps
Models with R5A/W Icemaker
U150R5A/W, U150NR5A/W – Icemaker 11.0 amps, dispenser 2.4
amps
U150BR5A/W – Icemaker 11.0 amps, dispenser 4.4 amps
U150R10A/W, U150NR10A/W – (2) icemakers 11.0 amps each,
dispenser 2.4 amps
U150B10A/W – (2) icemakers 11.0 amps each, dispenser 4.4
amps
• Equipment ground required.
• Separate circuit and disconnects required for each icemaker
and dispenser. Disconnects suggested within 10 ft (3m) of
dispenser and icemaker(s).
Condenser type – A = air-cooled, W = water-cooled
Remote icemaker(s) capacity and refrigerant – 4 = 400 lbs (181kg)/day, R12;
5 = 400 lbs (181kg)/day, R22; 8 = 800 lbs (363kg)/day, R12; 10 = 800 lbs
(363kg)/day, R22
B = with integral beverage cooling. Absence of a B = no integral beverage
cooling. N = no beverage rail or valves.
Approximate storage capacity in lbs
Dispenser configuration – U = undercounter
2
Alternate electrical - 230V, 50Hz, 1 phase
Separate circuit and disconnects required for each icemaker
and dispenser. Max. fuse size 15 amps per circuit
Manual load models
U150N – dispenser 1.7 amps
U150 – dispenser 1.7 amps
U150B – dispenser 2.2 amps
Models with R4A/W Icemaker
U150R4A/W, U150NR4A/W – 7.7 amps
U150BR4A/W – 8.2 amps
U150R8A/W, U150NR8A/W – 13.7 amps
U150BR8A/W – 14.2 amps
Models with R5A/W Icemaker
U150R5A/W, U150NR5A/W – Icemaker 6.0 amps,
dispenser 1.7 amps
U150BR5A/W – Icemaker 6.0 amps, dispenser 2.2 amps
U150R10A/W, U150NR10A/W – (2) icemakers 6.0 amps
each, dispenser 1.7 amps
U150B10A/W – (2) icemakers 6.0 amps each, dispenser 2.2
amps

Advertisement