Follett C125A Installation, Operation And Service Manual page 20

12 series ice and water dispensers
Table of Contents

Advertisement

When the 20M LED goes off, the 60 Minute Timer LED (60M) comes on. The 60M LED will remain on for 60
minutes from restart. A lighted 60M LED tells the technician that the icemaker has experienced an over-torque
condition. If the icemaker runs without problems for 60 minutes and no additional torque errors occur, the 60M
LED will go off.
W
COMPRESSOR
The second error (2ND) LED will come on if an over-torque condition occurs while the 60M LED is still lighted.
The 2ND LED will indicate to the technician that two consecutive over-torque situations have occurred. The
icemaker will be shut down at this time and will not restart unless the manual reset button is pressed.
W
COMPRESSOR
Diagnostic sequence – Stage 8
INPUT
POWER
B
G
GRD
X
WHITE
FAN
BLACK
WHITE
M
BLACK
BLACK
1
R
M
C
ORANGE
S
L
S
BLACK
RED
BLACK
WHITE
Diagnostic sequence – Stage 9
INPUT
POWER
B
G
GRD
X
WHITE
FAN
BLACK
WHITE
M
BLACK
BLACK
1
R
M
C
ORANGE
S
L
S
BLACK
RED
BLACK
WHITE
WATER
SENSOR
PWR
CONTROL
RESET
GRD
BOARD
DR
L1
L1
C
L2
20M
L2
60M
L2
L2
2ND
L2
WTR
B-T
COMPRESSOR
B-E
FAN
DRIVE
L2
L1
3
WHITE
4
GEARMOTOR
BLACK
WATER
SENSOR
PWR
CONTROL
RESET
GRD
BOARD
DR
L1
L1
C
L2
20M
L2
60M
L2
L2
2ND
L2
WTR
B-T
COMPRESSOR
B-E
FAN
DRIVE
L2
L1
3
WHITE
4
GEARMOTOR
BLACK
20
BIN SIGNAL
SWITCH
BIN T-STAT
RED
RED
COMPRESSOR
SWITCH
BIN SIGNAL
SWITCH
BIN T-STAT
RED
RED
COMPRESSOR
SWITCH

Advertisement

Table of Contents
loading

This manual is also suitable for:

H125a

Table of Contents