Specifications - Follett Symphony 12CI400A Installation, Operation And Service Manual

Ice and water dispensers 12 series
Table of Contents

Advertisement

16"
(407mm)
Dispenser front view

Specifications

Electrical
115V, 60Hz, 1 phase, 13.0 amps. Connect to 20 amp circuit, fuse or breaker.
Note: It is preferred that circuit be protected by a GFCI.
Furnished with 6 ft (1.8m) power cord with a 90° hospital grade 5-20 plug
Ambient
Air temp
100°F/38°C Max.
Water temp
90°F/32°C Max.
Water pressure
70 P.S.I. Max.
Plumbing
12CI400A
Dispenser drain
3/4" FPT
Water inlet
3/8" FPT
Note: Water shut-off recommended within 10 feet (3m) of dispenser. Drain to be hard-piped and insulated.
Maintain at least 1/4" per foot (20mm per 1m run) of slope.
Ventilation clearances
6" (153mm) on right side of dispenser, 6" (153mm) at top for ventilation and 12" (305mm) at top recommended
for service.
Note: Do NOT block right side air intake or top air exhaust.
Dry weight
175 lbs (79.4kg)
22.625"
(575mm)
Air
intake
18"
(458mm)
4"
23.5"
(102mm)
(597mm)
Dispenser side view
50°F/10°C Min. (Best performance below 80˚F/27˚C)
40°F/4°C Min. (Best performance below 70˚F/21˚C)
10 P.S.I. Min.
12HI400A
3/4" FPT
3/8" FPT
4
air exhaust
32.5"
(826mm)
3/4" FPT drain
air
intake
Dispenser rear view
3/8" FPT
water inlet
power cord