• All dispensers must be installed level in both directions to ensure proper operation.
• Required service and ventilation clearances: 6" (153mm) on right side of dispenser, 12" (305mm) at top.
• Countertop units installed without legs provide the option of taking utilities out bottom or back of dispenser
(on wall mount units and countertop units with legs, utilities exit out back). See counter cut-out drawings
for bottom exiting utilities on units with and without drain pans. For installations where utilities exit through
back of dispenser, refer to back view drawings.
• Wall mount models without drain pan are designed for use above sinks.
• Wall mount models require 30" (762mm) deep counters. Front of sinks must be installed no more than 2"
(51mm) from front of counter.

Installing countertop dispensers without legs

1.
Position dispenser in desired location,
mark dispenser outline on counter and
remove dispenser.
2.
Regardless of whether utilities will exit
through back or bottom of dispenser, drill
four (4) 7/16" holes in counter to anchor
dispenser to counter (Fig. 1).
3.
For utilities exiting through bottom
only:
(a) Make cutout as shown in Fig. 1.
(b) Move plug from drain T to back of
unit (Fig. 2).
(c) Remove 90 degree compression
fitting and poly tube.
(d) Run water line to 3/8" FPT water
inlet.
4.
For all units:
Apply a thick bead - approximately 1/4"
(6 mm) diameter - of NSF listed silicone
sealant (Dow Corning RTV-732 or
equivalent) 1/4" (6mm) inside marked
outline of dispenser.
5.
Carefully lower dispenser on counter in
proper position and secure to counter
with four (4) 3/8"-16NC bolts.
6.
Smooth excess sealant around outside
of dispenser.
7.
Make final connections.

Installation procedures

Before you begin
.437"
diameter
6
Fig. 1
Counter information
16"
(407mm)
14.4"
(266mm)
12"
(305mm)
(51mm)
cutout for
connections
through
bottom
0.8"
(2mm)
1.5"
(38mm)
2"
1" (26mm)
12"
(305mm)
15.9"
(404mm)
18"
(458mm)
4"
(102mm)

Advertisement