Installation Unit installation
Carrier Transicold Europe
3. Roof top and roof cut mounting installation:
Drill the 4 fixing holes ∅ 10 mm in the bottom cover of
the unit.
4. Nosemount installation:
Use the 4 fixing holes at the rear of the frame (refer to
"Box preparation/Drilling/Nosemount – page11)
5. Using the lifting device (P/N 07-60110-00) put the unit in
place on the 4 silent blocks.
6. Roof top and roof cut mounting installation:
Fix the unit with the 4 silent blocks and bolts delivered in
the packaging.
7. Nosemount installation:
Fix the unit with the 4 bolts.