Operation & Service Manual
Installation Battery & ignition key harness fitting
Carrier Transicold Europe
7. Heat the retractable sleeve to insulate the connector.
8. Strip the battery ground (-) (35mm
terminal with the adapted crimping tool.
NOTE : Soft-solder is recommended.
9. Install the 80 amps fuse holder as closed as possible from
the 12 Vdc battery.
10. Put grease on the fuse holder connections.
31/03/07
2
black) – crimp the
Viento - Installation/Rev- #45/54