Compaq ProLiant Clusters HA/F100 Administrator's Manual page 51

Hide thumbs Also See for ProLiant Clusters HA/F100:
Table of Contents

Advertisement

Designing the Compaq ProLiant Clusters HA/F100 and HA/F200 2-17
Recommended Cluster Communication Strategy
The past two sections discussed the redundancy of intracluster and
cluster-to-LAN communication. However, to obtain the most benefit while
minimizing cost and complexity, view cluster communications as a single
entity.
To create redundancy for both intracluster and cluster-to-LAN
communication, first, employ physical hardware redundancy for the LAN
NICs. Second, configure the Microsoft clustering software to use both the
primary and redundant LAN NIC as backup for intracluster communication.
With this strategy, your cluster can continue normal operations (without a
failover event) when each of the following points of failure are encountered:
I
Failure of the interconnect card
I
Failure of the interconnect cable
I
Failure of the port on the LAN NIC
I
Failure of the LAN NIC (if redundant NICs, as opposed to dual-ported
NICs, are used)
I
Failure of the Ethernet cable running from a cluster node to the Ethernet
hub (which connects to the LAN)
The following examples describe how to physically set up your cluster nodes
to employ the Compaq-recommended strategy.