Compaq ProLiant Clusters HA/F100 Administrator's Manual page 122

Hide thumbs Also See for ProLiant Clusters HA/F100:
Table of Contents

Advertisement

4. Install the latest drivers and server support software by running the
Compaq Support Paq for Windows 2000 on Node 1:
a. This can be done by inserting the SmartStart CD and selecting Start
and then Run. In the dialog box that displays, type
X:\cpqsupsw\ntcsp\setup.exe
your CD-ROM drive.
b. You can also acquire and run the latest Compaq Support Paq from
the Compaq website (
c. After the installation is completed, the Compaq Support Paq window
will show, the drivers that were updated and the drivers that were not
installed due to a current version of the driver on the node or due to a
lack of hardware on the node.
5. Install Windows 2000 Service Pack 1 on Node 1.
6. Verify that the Cluster Service has started and that Node 1 has rejoined
the cluster. Open Cluster Administrator by clicking Start, Programs,
Administrative Tools, Cluster Administrator. As the Cluster
Administrator opens, an error will display. This error is a result of the
additional resources that Windows 2000 Advanced Server offers
Microsoft Cluster Server. This error will not display when Node 2 is
upgraded to Windows 2000 Advanced Server). From the error screen,
select Yes To All to open Cluster Administrator.
7. Verify the RA4000Controller Firmware Version Levels by running the
online Array Configuration Utility on Node 1, selecting the RA4000
Controller and then clicking on the More Information tab. The online
Array Configuration Utility is installed by running the Compaq Support
Paq for Windows 2000 in Step 4 of this migration procedure.
Determine the firmware version on newly purchased controllers by
reviewing the documentation that came with the controllers.
IMPORTANT: If the firmware version levels are not the same and at version 2.58 or later
you must update them to the same level as specified in Step 10.
8. Install New Hardware:
a. Shut down node 1 and install the second host bus adapter, additional
redundant RA4000 Controllers, the additional Fibre Channel storage
hub or FC-AL switch and cables as necessary.
IMPORTANT: To ensure that your HA/F200 cluster fails over properly, attach each host
bus adapter in a single server to a different Fibre Channel storage hub or FC-AL switch,
and attach each RA4000 Controller in the RA4000/4100 to a different Fibre Channel
storage hub or FC-AL switch. See the installation procedures in Chapter 3.
Upgrading the ProLiant Clusters HA/F100 and HA/F200 4-17
where X is the drive letter associated with
http://www.compaq.com/support
).

Advertisement

Table of Contents
loading

This manual is also suitable for:

Proliant ha/f200

Table of Contents