4-8 Compaq ProLiant Clusters HA/F100 and HA/F200 Administrator Guide
8. Upgrade the RA4000 Controller firmware:
a. Create the Options ROMPaq diskettes from the Diskette Builder
Utility by inserting the SmartStart CD and selecting Start and then
Run. In the dialog box that displays, type
is the drive letter associated with your CD-ROM drive.
NOTE: You can acquire and run the latest Options ROMPaq from the Compaq website
(http://www.compaq.com/support).
b. Power down Node 1 and Node 2.
c. Insert the Options ROMPaq diskette into Node 1 and restart the
node. Run Options ROMPaq and choose to update the firmware on
the RA4000 Controllers.
d. Power down the storage and Node 1 after the firmware update
completes.
e. Power on the storage, wait for the drives to spin, and then power on
Node 1.
9. Move all cluster resources from Node 2 to Node 1. Skip this step if the
firmware update procedure was performed (Step 8).
10. Upgrade Node 2 by repeating steps 2 through 6 for Node 2 and then
continuing with Step 11.
11. Verify the cluster by running the Compaq Cluster Verification Utility.
Instructions for installing and running this utility can be found in
Chapter 3 of this guide.
12. Install your applications, managing and monitoring software as needed.
These may include Compaq Insight Manager, Compaq Insight Manager
XE, Compaq Intelligent Cluster Administrator, and other applications
needed on this cluster.
where X
X:\dskbldr\setup.exe