Removing The Left Frame; Removing The Power Supply Shield Plate; Removing The Fixing Film Unit - Canon LaserBase MF5600 Service Manual

Laserbase mf5600 series
Hide thumbs Also See for LaserBase MF5600:
Table of Contents

Advertisement

Chapter 3
3.6.1.15 Removing the Left
Frame
1) Remove the cable [1] out of the cable guide.
2) Remove the three screws [2] and then removes the
left frame [3].
[3]
[2]
[1]
F-3-430
3.6.1.16 Removing the Power
Supply Shield Plate
1) Remove the five screws [1] to remove the power
supply shield plate [2].
[2]
[1]
[1]
F-3-431
3.6.1.17 Removing the Fixing
Film Unit
1) Remove the two screws [1] and take off the Fixing
cover [2].
3-100
0002-7479
[2]
0003-7594
0006-3727
[1]
[2]
F-3-432
2) Remove the two screws [1]. Remove the Fixing
entrance guide [2] by sliding it sideways back and
forth.
[1]
[2]
F-3-433
3) Disengage the connector [1] of the power supply
board.
4) Remove the grounding springs and the pressure
springs [2] on both sides.
5) Remove the pressure plates [3] on both sides.
[3]
[2]
[1]
[2]
F-3-434

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Laserbase mf5650