Chapter 3
3.5.6.9 Removing the Power
Supply Shield Plate
1) Remove the five screws [1] to remove the power
supply shield plate [2].
[2]
[1]
F-3-397
3.5.6.10 Removing the Power
Supply Assembly
1) Remove the connector [1] and remove the cable
from the cable guide.
[1]
F-3-398
2) Remove the three screws [1]. (The external cover is
omitted from the illustration below to show the
instructions clearly.)
3) Remove the four connectors [2] as well as the flat
cable [3] on the DCNT board.
3-92
0002-7603
[1]
F-3-399
4) As you remove the bosses on both sides [1], lower
the front part of the power supply assembly [2].
Then pull it to remove the power supply assembly.
0006-3704
F-3-400
3.5.6.11 Removing the Main
Motor
1) Place the main unit down on its front face (so that
the interior of the main unit is easily visible).
2) Remove the two screws [1] to remove the main
motor [2].
[1]
F-3-401
[2]
[2]
[2]
[1]
[2]
[3]
[1]
0002-7607