SM 2547-1

Safety Check

Make sure that parts and wires have been returned to the correct positions.
Completely assemble the projector before doing an electrical safety test.
The safety tests:
Use a safety tester that measures all 3 tests at one time.
Such a test device would be a Mini Tester 0701 N (Manufacturer:Gossen, Germany) or an equivalent device.
Details for safety standards can be found in the regulations:
Prerequisites for measurements:
-
The projector is energized
-
FUSE with VOLTAGE SELECTOR insert
-
COVERS in place
-
LAMP MODULE installed
Test values for Mini Tester 0701N
-
Ground Continuity Test
-
Insulation Resistance Test
-
Equivalent Leakage Current
Interfaces
Models 7020 and 9020 have an accessory slot. The 7/12pin module from Kodak is safety tested, and has
approval from VDE and other institutions. If an OEM module is installed, inform the customer:
-
the OEM is responsible for the safety and function of the module.
-
the module is not part of the repair order.
-
the specifications and safety warnings for the accessory in the slot are found in the
"Operator's Manual".
Kodak AG, Stuttgart
NOTE
Check the area around the repaired location.
Ground Continuity Test
Insulation Resistance Test
Equivalent Leakage Current Test
IEC 380, 435, 950,
UL 478, 1012.
.......<
.......<
.......<
300 mOHM
= 0,5 OHM
= 7 mA
1-5