Service Manual
FAN, KEYBOARD PCB and TRAY MOTION PCB
1
.
Remove the UPPER HOUSING. See page 4-1.
2
.
Remove the CENTER HOUSING. See page 4-4.
3
.
Disconnect the FAN MOTORS.
4
.
Remove the FAN.
5
.
Disconnect the KEYBOARD PCB.
6
.
Disconnect the TRAY MOTION PCB.
Do not clean the FAN with compressed air because the rotary wings would be demaged!