Utility mode
6
Touch the button for the paper tray to be set.
7
Press the [Start] key.
Only paper loaded into the bypass tray can be used.
A test pattern is printed.
8
Check that the distance from the starting print position of the test
pattern to the edge of the paper (b) is 3 mm (±0.5 mm).
If the distance is 2.4 mm or less, touch [+] to increase the
adjustment (between 0.2 mm and 3.0 mm).
If the distance is 3.6 mm or more, touch [-] to reduce the adjustment
(between -0.2 mm and -3.0 mm).
If the distance is between 2.5 mm and 3.5 mm, continue with step
10.
Each time [+] or [-] is touched, the value is increased or decreased
by one increment.
9
Press the [Start] key.
The adjusted test pattern is printed.