Description of Fault Codes

Each Fault Code consists of an "F" followed by a number, dash and a number or letter. The following table
describes each Fault Code and the component to troubleshoot.
To view the most recent fault code:
1. Press and hold the Cancel and Broil pads for 3 seconds at power-up, or within 5 minutes of power-up.
2. Once the control has entered the "Quick Test" mode, release both pads.
3. Press the Cook Time pad to view the most recent fault (displayed in the control display window).
Fault Code
F0-0
No Fault.
Oven temperature above 650° F (343° C)
F1-1
in bake mode.
Oven temperature above 950° F (510° C)
F1-3
during a clean cycle.
F1-5
Cancel pad not responding.
F1-7
Membrane disconnected.
F1-8
Shorted key (pad) in membrane switch.
F1-9
Internal control communication errors.
Lock/unlock switch state not advancing to
F1-A
control.
Oven door switch state not advancing to
F1-C
control.
F1-E
Control not calibrated.
Jumper not removed from printed circuit
F1-F
board (PCB).
F1-H
EEPROM error.
F1-N
Internal voltage for slave micro incorrect.
F3-1
Open or shorted sensor.
F8
Shorted meat probe.
F9-1
Oven door will not lock.
F9-2
Oven door will not unlock.
Oven door status is both locked and
F9-3
unlocked.
©2005 Maytag Services
!
WARNING
Description
16026016
Component to Troubleshoot/Replace
None.
Ohm sensor and harness (see "Oven Sensor"
chart). If OK, change control.
Ohm sensor and harness (see "Oven Sensor"
chart). If OK, change control.
Ensure ribbon cable is securely connected, inspect
ribbon cable and connector (shorts, breakage,
corrosion, etc.). If OK, replace control.
Ensure ribbon cable is securely connected, inspect
ribbon cable and connector (shorts, breakage,
corrosion, etc.). If OK, replace control.
Ensure ribbon cable is securely connected, inspect
ribbon cable and connector (shorts, breakage,
corrosion, etc.). If OK, replace control.
Replace control.
Check connections, harness, and motor. If OK,
replace control.
Check connections, harness, and motor. If OK,
replace control.
Replace control.
Remove jumper from PCB.
Replace control.
Replace control.
Ohm sensor and harness.
Check probe jack and harness probe jack harness.
If OK, check meat probe (see "Meat Probe" chart).
Check wire connections. If OK, replace motorized
door lock.
Check wire connections. If OK, replace motorized
door lock.
Check wire connections. If OK, replace motorized
door lock.