Testing Procedures; Component Testing Procedures - Jenn-Air JDS8850AAB Service Manual

Dual fuel slide-in range
Table of Contents

Advertisement

Testing Procedures

To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless
testing requires power.

Component Testing Procedures

Illustration
Oven light housing
All models
Step-down
Primary
Primary
transformer
All models
Secondary
Secondary
Door plunger switch
All models
Autolatch assembly
All models
Pressure regulator
270° valve
Model JDS8850A**
Spark switch
Model JDS8850A**
Spark ignition
electrode
Model JDS8850A**
Venturi, right front,
left front, left rear
burners
Model JDS8850A**
Venturi, right rear
burner
Model JDS8850A**
16
!
Component
Disconnect connector and test
resistance of terminals........................
Measure voltage at oven light.............
Measure voltage at:
Primary terminals ............................
Secondary terminals .......................
Remove switch from unit and
measure the following points:
COM to NO ..................................... Plunger in continuity, plunger out
Disconnect wires and test for
continuity per wiring diagram..............
Refer to Parts Manual for correct
autolatch switch associated with the
correct manufacturing number.
Verify gas pressure (W.C.P.)..............
If on LP service verify proper gas
supply conversion.
Verify gas is supplied.
6.5 K btu
Adjust set screw for simmer control.
9.1 K btu
10.5 K btu
12 K btu
Test for voltage at terminals ...............
Disconnect wiring and check for
continuity in LITE position...................
Test for resistance of spark lead ........
Test ignitor to chassis.........................
Shutter settings .................................. Nominal: .038" (tolerance: .035" to
Shutter settings .................................. Nominal: .038" (tolerance: .035" to
WARNING
Test Procedure
16026016
Results
Verify bulb is plugged in properly.
Indicates continuity with bulb installed.
12 VAC, see wiring diagram for
terminal identification.
If no voltage is present at oven light,
check wiring or light switches.
120 VAC (tolerance: 108 to 127 VAC)
10W load (bulb): 11.4 to 11.8 VAC
20W load (bulb): 10.8 to 11.4 VAC
infinity.
See wiring diagram for schematic
layout.
Access assembly by removing two
screws from the front and lowering
control panel.
Common is in neutral position unless
locking or unlocking autolatch
assembly.
5" Natural
10" LP/propane
120 VAC
Continuity in LITE position.
Continuity
No continuity from ignitor to chassis.
.041")
.041")
©2005 Maytag Services

Hide quick links: