Testing Procedures
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to oven before servicing,
unless testing requires power and/or gas.
Component
Control Panel Assembly
20
!
WARNING
Test Procedure
Closed circuitry resistance
(defined as continuity):
1350 – 2250 Ω for Cancel pads 1 & 20
1275 – 2125 Ω for Cancel pads 2 & 19
320 – 2200 Ω for all other pads
Open circuitry resistance:
Greater than 10 MΩ
Pin 20
Pin 1
16026016
Results
Pad
Trace
1
7 & 8
2
14 & 15
3
10 & 14
4
6 & 7
5
6 & 8
6
5 & 6
7
4 & 5
8
4 & 6
9
3 & 4
0
3 & 6
1 & 2 or
Cancel
1 & 19 or
2 & 20 or
19 & 20
Clock
13 & 14
Quick Preheat
16 & 18
Bake
15 & 16
Broil
16 & 17
Keep Warm
12 & 13
6 & 10
Convect Warm
Convect Roast
3 & 18
Cook Time
10 & 18
Stop Time
14 & 18
Clean
15 & 18
Proofing
8 & 10
Drying
9 & 10
Meat Probe
6 & 18
Vent Fan
11 & 12
Auto Set
17 & 18
Timer 1
12 & 14
Timer 2
10 & 12
Oven Light
10 & 11
©2005 Maytag Services
Measurement
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity