Refrigeration Air Flow - Whirlpool Polara GR556LRK Service Manual

Refrigerated range
Table of Contents

Advertisement

EVAPORATOR AIR FLOW
Air flow through the oven cavity and evaporator
is basically a closed loop system, although
some of the air will be drawn out through the
oven vent in the cooktop, and the bottom of the
oven door.
Air is drawn out of the cool air return vent in the
bottom of the oven cavity, where it moves
through the inlet of the cooling module to the
evaporator. The air moves through the evapo-
rator, where it is cooled, and forced through the
air outlet. The cooled air travels up the left side
Oven Vent
Oven Cavity
Air Inlet
Oven Cavity
Cool Air Return
Air Inlet To
Evaporator
Air Outlet From
Evaporator

REFRIGERATION AIR FLOW

Cooled Air In
Cool Air Return
Evaporator
of the unit, and enters the top of the oven cavity
through the air inlet.
The refrigerated air circulates through the oven
cavity, where it is warmed by the food, and then
drawn back out the cool air return vent to the
evaporator.
CONDENSER AIR FLOW
The compressor is cooled by room air, which
then flows right to left through the condenser,
and back into the lower compartment of the
unit.
POLARA
Condenser Air
Condenser
3-3
Oven Floor
Compressor
Cooling Module