Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
THERMAL CUTOFF
Refer to page 4-2 for the procedure for servic-
ing a thermal cutoff.
1.
Unplug the refrigerated range or discon-
nect the power.
2.
Set the ohmmeter to the R x 1 scale.
3.
For the thermal cutoff (N.O.) with the
narrow (3/16") terminals, touch the ohm-
meter test leads to the terminals. The
meter should indicate an open circuit (in-
finite).
4.
For the thermal cutoff (N.C.) with the
wide (1/4") terminals, touch the ohmme-
ter test leads to the terminals. The meter
should indicate continuity (0 Ω).
Electrical Shock Hazard
Thermal Cutoff With
1/4" Terminals
Opens @ 96°C (205°F)
Closes @ 74°C (165°F)
Thermal Cutoff With
3/16" Terminals
Opens @ 70°C (158°F)
Closes @ 60°C (140°F)
WARNING
FEATURE BOARD
P2300
1
2
3
4
x
6
Refer to page 4-17 for the procedure for servic-
ing the feature board.
1.
Unplug the refrigerated range or discon-
nect the power.
2.
Set the ohmmeter to the R x 1 scale.
3.
Touch one of the ohmmeter leads to the
wire connector at pin 1 and the other lead
to the wire connector at pin 4 of connector
P2301. The meter should indicate a closed
circuit (0 Ω).
4.
Touch one of the ohmmeter leads to the
wire connector at pin 2 and the other lead
to the wire connector at pin 3 of connector
P2301. The meter should indicate an open
circuit (infinite).
5-4
P2301 - Pin 1
K2003
P2301
3
2
1
4
2
3
K2000
3
2
4
4
FUSE 3AB SLO-BLO 12A/250V AX