Registration Sensor Actuator (PL 9.1.9) and
Registration Sensor (PL 9.1.8)
Removal of Actuator
1.
Remove the Chute Assembly Registration (page 8-71).
2.
Shift the actuator (item #1) to the left, lift up on the right side and remove.
3.
Remove the actuator spring (item #2) from the Actuator.
Note
Make note of the orientation of the spring for reassembly.
FRONT
Service Parts Disassembly
CHUTE ASSY REGI
TOP
1
2
6250-207
8-73