AT&T 6300 Service Manual page 62

Hide thumbs Also See for 6300:
Table of Contents

Advertisement

SYSTEM OVERVIEW
LA16 POWER SUPPLY
The general output specifications for the LA16 power supply is
shown in the following table (Figure 2-19). It shows the minimum
and maximum values of current generated per the output voltages.
The power supply unit is able to provide a stationary power of
163 watts.
Nominal
Voltage
Tolerance
Minimum
Current
Maximum
Current
Maximum
Ripple
+5 V
±5%
6.2
A
16.8
A
50 mVp-p
+12 V (Note)
±5%
0.9
A
4.5 A
100 mVp-p
+15 V
±10%
1.0
A
2.4
A
250 mVp-p
-12 V
±5%
0
0.25
A
100 mVp-p
Figure 2-19. Power Supply Output Characteristics
Note: An impulsive repetitive load with maximum 1/5
duty cycle and behavior is allowed on the +12 V. An
impulsive load is allowed on the + 12 V to be added to the
static load in the power-on transition where a deviation
from the rated tolerances of the output voltages is allowed.
The worst load crossings allowed with no power take-off on
+
15 V are as follows:
I
(+12 V)
0.9 (min)
I (+5)
14.3A
(max)
I
(+5 V)
6.2A (min)
I (+12)
4.5A
(max).
2-47