Move the spindle head to the front left of the workpiece table, then attach the vacuum adapter for chip cleaning as shown in
the figure. Using the vacuum adapter for chip cleaning enables the vacuum cleaner to take up cutting waste during cutting,
which can help keep scattering of cutting waste to a minimum.
 P. 44, "Manual Movement"
Front
Nose unit
Vacuum adapter
clamp
Retaining
screw
Tab
Position so that the retaining screw
for the nose unit is between the tabs
of the clamp.
Top
Hose
Provide a gap large enough
to ensure no striking.
5-1 Attaching the Vacuum Adapter for Chip Cleaning
Tab
Clamp
Rear
32mm
(1.3 in.)
Secure in place
at the locations
where the audible
click is heard.
Hose
Opening the clamp
Chapter 5 Feature reference
Bar
Hose
Pass through above the bar.