Test the Tilt Sensor
9 Pull out the platform red Emergency Stop button
to the
position. Turn the key switch to
ON
platform control.
10 Open the tank side turntable
cover and locate the tilt sensor
next to the control box.
11 Press down one side of the tilt
sensor.
Result: The alarm, located in
the platform, should sound.
Test Auxiliary Controls
12 Turn the key switch to ground control and shut
the engine off.
13 Pull out the red Emergency Stop button to the
position.
ON
14 Simultaneously hold the auxiliary power switch
on and activate each boom function toggle
switch.
Note: To conserve battery power, test each
function through a partial cycle.
Result: All boom functions should operate.
Part No. 43648
At the Platform Controls
Test Emergency Stop
15 Turn the key switch to platform control and
restart the engine.
16 Push in the platform red Emergency Stop button
to the
Result: The engine should turn off and all
functions should not operate.
17 Pull out the red Emergency Stop button and
restart the engine.
Test the Hydraulic Oil Return Filter
18 Move the engine idle select switch to high idel
(rabbit symbol).
19 Locate and check the
hydraulic filter condition
indicator.
Result: The filter should
be operating with the
plunger in the green
area.
20 Move the engine idle select switch to foot switch
activated high idle (rabbit and foot switch
symbol).
Test the Service Horn
19 Push the horn button.
Result: The service horn should sound.