Operating Instructions - Genie S-60 Operator's Manual

Hide thumbs Also See for S-60:
Table of Contents

Advertisement

Operator's Manual

Operating Instructions

Do Not Operate Unless:
You learn and practice the principles of safe
machine operation contained in this operator's
manual.
1 Avoid hazardous situations.
2 Always perform a pre-operation
inspection.
3 Always perform function tests prior to use.
4 Inspect the work place.
5 Only use the machine as it was intended.
Fundamentals
The Operating Instructions section provides
instructions for each aspect of machine operation.
It is the operator's responsibility to follow all the
safety rules and instructions in the operator's,
safety and responsibilities manuals.
Using the machine for anything other than lifting
personnel and tools to an aerial work site is unsafe
and dangerous.
Only trained and authorized personnel should be
permitted to operate a machine. If more than one
operator is expected to use a machine at different
times in the same work shift, they must all be
qualified operators and are all expected to follow
all safety rules and instructions in the operator's,
safety and responsibilities manuals. That means
every new operator should perform a pre-
operation inspection, function tests, and a work
place inspection before using the machine.
22
Starting the Engine
1 At the ground controls, turn the key switch to
the desired position.
2 Be sure both ground and platform control red
Emergency Stop buttons are pulled out to the
position.
3 Gasoline/LPG models: Choose fuel by moving
the fuel select switch to the
desired position.
4 Move the engine start toggle
switch to either side. If the engine
fails to start or dies, the restart
delay will disable the start switch for
3 seconds.
If the engine fails to start after 15 seconds of
cranking, determine the cause and repair any
malfunction. Wait 60 seconds before trying to start
again.
All models: In extreme cold conditions, 20°F (-6°C)
and below, warm the engine for 5 minutes to
prevent hydraulic system damage.
Gasoline/LPG models:In extreme cold conditions,
20°F (-6°C) and below, the machine should be
started on gasoline, then switched to LPG.
Emergency Stop
Push in either the ground or platform red
Emergency Stop button to the
all functions and turn the engine off.
Repair any function that operates when the
Emergency Stop button is pushed in.
Selecting and operating the ground controls will
override the platform Emergency Stop button.
Genie S-60 & Genie S-65
Second Edition • Fifth Printing
position to stop
OFF
Part No. 43648
ON

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S-65

Table of Contents