Panasonic WV-CS554 Operating Instructions Manual page 9

Combination camera
Hide thumbs Also See for WV-CS554:
Table of Contents

Advertisement

AUTO PAN KEY
This setting assigns SEQ, SORT, AUTO PAN or PATROL (PLAY) to the AUTO key on the controller. After
this setting, the AUTO key performs as assigned.
Note: AUTO PAN LED on the controller does not light if other than AUTO PAN is assigned.
DIGITAL FLIP ON/OFF
Tilt range is limited within 0° to 90° if OFF is selected. If ON is selected it widens the range up to 180° with
the digital flip that reverses horizontal and vertical scanning when the camera is tilted through the 90°
point (Downright position if the camera is installed on a ceiling). Tilt range narrows from 180° to 90° if PAN
LIMIT is set to ON.
LOCAL/REMOTE
This setting determines whether the camera continues or stops the ongoing auto operation when the
System Controller is turned off.
LOCAL: The camera continues operating in auto mode when the controller is turned OFF.
REMOTE: The camera stops operating in auto mode approx. 1 minute after the controller is turned off.
See page 23 for the setting.
SPECIAL 1
(1) Privacy Zone ON/OFF (PRIVACY ZONE)
This setting is to mask unwanted zones, hiding them from display on the monitor. When (DIS) follows
ON or OFF, set PASSWORD LOCK to OFF if you wish to change this setting. Up to 8 zones can be
registered. Submenus are provided for zone number selection and for parameter setting. See page
23 for details.
(2) Proportional Pan-Tilt Speed ON/OFF (PROPO. P/T)
If ON is selected, the zoom ratio changes corresponding to pan-tilt speed. For example, pan-tilt
speed slows down with zoom in. See page 24 for details.
(3) Area Title ON (NESW), ON (USER), OFF
Up to 16 area titles can be added to specific scenes by DIRECTION (NESW) or alphanumerical
(USER) naming. The titles are displayed right under the camera title on the monitor when the camera
turns positions to area titles. See page 25 for details.
(4) Patrol Learn
A set of manual operations is stored (LEARN), reproduced (PLAY) or turned inactive (OFF). Patrol
operation stops if SEQ, SORT or AUTO PAN is set to AUTO MODE on the SETUP menu. See page 27
for details.
(5) Alarm IN/OUT (ALARM IN/OUT)
Alarm input and output are set on the submenu. Preset positions are assigned to ALARM IN 1 to 4. If
inputs are supplied via the ALARM INPUT connector, the camera turns to respective positions. The
camera then sends output signals via the ALARM OUT connector or the coaxial cable to the external
devices. B/W may be chosen instead of a preset position if light is so insufficient that color noise may
disturb picture clarity. CNT-CLS (Contact Closure) 1,2 and COAX ALM OUT are for alarm output set-
ting. See page 28 for details.
10

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wv-cs854

Table of Contents