5-17 ELECTRICAL SYSTEM
◉ COMBINATION METER
Remove the combination meter.
Disassemble the combination meter as shown in the
illustration.
� INSPECTION
Using the pocket tester, check the continuity between
lead wires in the following illustration.
If the continuity measured incorrect, replace the respec-
tive part.
Pocket tester : 09900 - 25002
CAUTION
When making this test, it is not necessary to
remove the combination meter.