◉ INSPECTION
� MAGNETO
Using the pocket tester, measure the resistance
between the lead wires in the following table.
Pick-up coil
Charging coil
Pocket Tester : 09900 - 25002
CAUTION
When mounting the stator on the magneto cover,
apply a small quantily of THREAD LOCK "1324
to the threaded parts of screws.
THREAD LOCK " 1324 "
WIRE COLOR
L
: Blue
G
: Green
Br
: Brown
B / Y : Black with Yellow tracer
O / B : Orange with Black tracer
G / W : Green with White tracer
B / W : Black with White tracer
W / L : White with Blue tracer
� CDI UNIT
Using the pocket (R × 1
tance between the lead wires in the following table.
1
2
1
2
5 ~ 100
3
10 ~ 100
4
5
30 ~ 150
6
10 ~ 100
7
8
10 ~ 50
Pocket Tester : 09900 - 25002
G - L Approx 90�110 Ϊ
Y - Y Approx 0.6�0.9 Ϊ
range), measure the resis-
� Probe of tester
3
4
5
6
7
30 ~ 200
30 ~ 200
30 ~ 200
30 ~ 200
5 ~ 50
5 ~ 50
2 ~ 50
5 ~ 50
5 ~ 50
2 ~ 50
5 ~ 50
5 ~ 50
1 ~ 30
30 ~150
30 ~ 150
10 ~ 100
5 ~ 50
10 ~ 100
2 ~50
5 ~30
2 ~30
2 ~50
Unit :
8
10 ~ 100
1 ~ 20
1 ~ 20
5 ~ 50
2 ~ 20
ELECTRICAL SYSTEM 5-4