Main code
Sub code
26
40
42
43
Y101700-5
Polygon motor OFF time setup
(Operation/Procedure)
1. When this simulation is executed, the currently set code number is displayed.
2. Enter the code number and press the START key, and the setting will be changed.
Code number
0
1
2
3
Transfer ON timing control setup
(Operation/Procedure)
1. When this simulation is executed, the currently set code number is displayed.
2. Enter the code number and press the START key, and the setting will be changed.
(For any number different from the following ones, the default time is automatically
set.)
Code number
0
1
2
3
4
5
6
7
8
9
Side void setup
(Operation/Procedure)
1. When this simulation is executed, the currently set code number of the side void
amount is displayed.
2. Enter the code number and press the start key. The setting is changed.
Code number
0
1
2
3
4
5
6
7
8
9
10
Service Manual
Content
Setting
0 sec
30 sec
60 sec
90 sec
Setting
Default (330 msec)
–40 msec
–30 msec
–20 msec
–10 msec
Default (330 msec)
+10 msec
+20 msec
+30 msec
+40 msec
Setting
0 mm
0.5 mm
1.0 mm
1.5 mm
2.0 mm *Default
2.5 mm
3.0 mm
3.5 mm
4.0 mm
4.5 mm
5.0 mm
6-9