(4) Remove the screw and remove the U-turn guide.
4.4.2.1 Pressure roller section disassembly
(5) Remove the three screws, remove the fusing cover lower
on the right side, and open the heat roller section.
(6) Remove the screw and remove the PPD2 sensor.
Y101700-5
(7) Remove the plate spring on the right and remove the
heater lamp.
(8) Remove the spring and remove the separation pawls
(3 pcs).
(9) Remove the E-ring and remove the reverse gate.