6. SIMULATIONS AND TROUBLE CODES

6.1 Simulations

6.1.1 List of simulations

Sim No.
Kind of main code Sub code
01
Optical system
05
Lamp ON
check
06
Machine
individual
load
operation
07
Aging
08
High
voltage
output check
10
Other
14
Trouble
reset
16
U2 Trouble
reset
20
Manteinance
counter clear
21
Counter setup
(When
manteinance)
22
Counter
display
24
Special counter
clear
25
Main motor ON
Y101700-5
Operation
01
Mirror scan operation
01
Operation panel display check
02
Fusing lamp ON + Cooling fan HIGH/LOW speed
03
Copy lamp ON
01
Paper feed solenoid ON
02
Resist solenoid ON
01
Warm up display and aging with jam
06
Intermittent aging
01
Developing bias
02
Main charger (Grid high)
03
Grid Voltage (Low)
06
Transfer charger.
None
Toner motor aging
None
Cancel troubles other than U2
None
Cancel of U2 trouble
01
Manteinance/mini-manteinance
counter clear
01
Manteinance cycle setup
02
Mini-manteinance cycle setup
01
Maintenance/mini-maintenance counter display
02
Maintenance/mini-maintenance preset display
05
Total counter display
06
Developer counter display
12
Drum counter display
14
P-ROM version display
06
Developer counter clear
07
Drum counter clear
01
Main motor system ON + Cooling fan low speed
10
Poligon motor ON
Service Manual