Olivetti d-Copia 12 Service Manual page 57

Hide thumbs Also See for d-Copia 12:
Table of Contents

Advertisement

Main code
Sub code
01
01
05
01
02
03
06
01
02
07
01
02
Y101700-5
Mirror scan operation
(Operation/Procedure)
1. When this simulation is executed, the mirror home position is detected.
Sensor name
Mirror home position sensor
2. When the _START key is pressed, scanning is executed at the speed corresponding
to the currently set copy magnification ratio.
The copy magnification ratio can be arbitrarily set with the magnification ratio select
key/zoom key.
Operation panel display check
When the PRINT switch is pressed, the LED on the operation panel is lighted for 5 sec.
Fusing lamp ON + cooling fan HIGH/LOW speed
(Operation/Procedure)
When the START key is pressed, the fusing lamp repeats ON (500ms) and OFF
(500msec) 5 times.
During this period, the cooling fan rotates in the high speed mode. After completion of
the operation, the cooling fan rotates in the low speed mode.
Copy lamp ON
(Operation/Procedure)
When the START key is pressed, the copy lamp is lighted for 5 sec.
Paper feed solenoid ON
(Operation/Procedure)
When the START key is pressed, the paper feed solenoid selected by the tray select key
repeats ON (500ms) and OFF (500ms) 20 times.
Resist solenoid ON
(Operation/Procedure)
When the START key is pressed, the resist solenoid (RRS) repeats ON (500ms) and
OFF (500ms) 20 times.
Warm-up display and aging with jam
(Operation/Procedure)
1. When the simulation is executed, warming up is started.
2. Warm-up time is counted and displayed every second on the copy quantity display.
3. After completion of warm-up, the time count is stopped and the ready lamp is lighted.
4. Press the clear key to clear the warm-up time display, set the copy quantity, and
press the START key, and the machine will copy the set quantity repeatedly.
Intermittent aging
(Operation/Procedure)
1. When the simulation is executed, warming up is started.
2. After completion of warm-up, the ready lamp is lighted.
3. Set the copy quantity and press the START key, and the machine will copy the set
quantity repeatedly.
4. After 3 sec of the interval time from completion of copying the set quantity, the
machine will resume copying.
5. The above operation 4 is repeated.
Service Manual
Content
Display lamp
OPC drum cartridge replacement lamp
6-3

Advertisement

Table of Contents
loading

Table of Contents