Main code
Sub code
26
20
30
37
39
6-8
Rear edge void setup
(Operation/Procedure)
1. When this simulation is executed, the currently set code number of rear edge void
setting is displayed.
2. Enter the code number of rear edge void setting and press the START key, and the
setting will be changed.
Code number
0
1
CE mark conformity control ON/OFF setup
(Operation/Procedure)
1. When this simulation is executed, the currently set code number of CE mark
application is displayed.
2. Enter the code number of CE mark application and press the START key, and the
setting will be changed.
Code number
0
1
Cancel of stop at developer life over
When this simulation is executed, the current set code is displayed. Enter a new code
and press the PRINT switch, and the entered code is registered.
Code number
0
1
Memory capacity setup
(Operation/Procedure)
1. When this simulation is executed, the currently set code number is displayed.
2. Enter the code number and press the START key, and the setting will be changed.
Code number
0
1
2
Service Manual
Content
Rear edge void setting
Rear edge void allowed
Rear edge void not allowed
CE mark application setting
CE mark application control OFF
CE mark application control ON
Setting
Stop at developer life over
Stop cancel at developer life over
Setting
No memory
4 Mbyte
6 Mbyte
Y101700-5