5.3.5 Copy density adjustment procedure

Use SIM 46-01 to set the copy density for each copy mode.
For selection of modes, use the copy mode select key.
5.3.5.1 Test chart (UKOG-0162FCZZ) setting
1) Place the test chart so that its edge is aligned with the
A4 (Letter) reference line on the document table. Then
place a B4 (14" x 8 1/2") white paper on the test chart
and close the document cover.
5.3.5.2 Perform the adjustment in each mode.
1) Execute SIM 46-1.
2) Select the mode to be adjusted with the exposure mode
select key. Set the exposure level to 3 for all adjustment.
(Except for the auto mode.)
Y101700-5
3) Make a copy.
Check the adjustment level (shown in the above table) of
the exposure test chart (Gray Scale).
(When too bright): Decrease the value displayed on the
copy quantity display.
(When too dark): Increase the value displayed on the
copy quantity display.
* The value can be set in the range of 1 - 99.
Service Manual