2.6.6.4 ACM and AFM Series Annunciators

ACM and AFM Series Annunciators provide visual indications of FACP status in
remote locations. Refer to the appropriate annunciator manual for information on
installation, wiring and operation.
Annunciator addressing is specific to the MS-9600 control panel. The following
table describes the annunciator addresses and the corresponding addressable
devices that will be annunciated at each annunciator address.
Annunciator Displays the Following Points
8 General System Status Points & Zones 1 - 56
Zones 57 - 99 & 4 NACs
Loop 1, Module Addresses 1 - 64
Loop 2, Module Addresses 1 - 64
Loop 1, Module Addresses 65 - 128
Loop 2, Module Addresses 65 - 128
Loop 1, Module Addresses 129 - 159 & Loop 2 Module Addresses 129 - 159
Loop 1, Detector Addresses 1 - 64
Loop 2, Detector Addresses 1 - 64
Loop 1, Detector Addresses 65 - 128
Loop 2, Detector Addresses 65 - 128
Loop 1 Detector Addresses 129 - 159 & Loop 2 Detector Addresses 129 - 159
not used
not used
not used
not used
not used
not used
not used
8 General System Status Points & Zones 1 - 56
Zones 57 - 99 & 4 NACs
Loop 1, Module Addresses 1 - 64
Loop 2, Module Addresses 1 - 64
Loop 1, Module Addresses 65 - 128
Loop 2, Module Addresses 65 - 128
Loop 1, Module Addresses 129 - 159 & Loop 2 Module Addresses 129 - 159
Loop 1, Detector Addresses 1 - 64
Loop 2, Detector Addresses 1 - 64
Loop 1, Detector Addresses 65 - 128
Loop 2, Detector Addresses 65 - 128
Loop 1 Detector Addresses 129 - 159 & Loop 2 Detector Addresses 129 - 159
not used
Important: If a UDACT-F is installed in the MS-9600 and selected in programming,
the control panel will automatically assign annunciator addresses 20 - 31 to the
UDACT-F and disable the selection of these addresses in programming for ACM
annunciators. Do not set any ACM annunciators to these addresses.
The MS-9600 must be programmed for the annunciators installed on the system.
Refer to "Annunciators/UDACT" on page 97 for information on UDACT-F and
annunciator programming. Make certain to program the annunciator addresses that
have been physically installed on the system.
Note: The 8 General System Status Points include the following:
General Alarm
General Trouble
General Supervisory
Alarm Silenced
System Off Normal
AC Loss
Battery Fault
NAC Fault
Optional Modules and Devices