2.2 Connectors
2.2.1 Interface Connectors
Refer to Section 2.1, Interfaces.
2.2.2 Power Supply Connector
This connector is used to connect the printer to an external power source.
1) Pin assignments:
NOTE: Be sure to ground the metal of the interface using the hole for the frame ground.
2) Connector model:
EPSON
Refer to Table 2.2.1.
Table 2.2.1 Power Supply Connector Pin Assignments
Pin Number
1
2
3
SHELL
Figure 2.2.1 Power Supply Connector
Printer side:
User side:
TITLE
TM-T90
Specification
(STANDARD)
Signal Name
+24 V
GND
NC
Frame GND
SHELL
Hosiden TCS7960-532010 or equivalent
Hosiden TCP8927-631100 or equivalent
Hosiden TCP8927-531100 or equivalent
SHEET
REVISION
NO.
NEXT
SHEET
F
30
29