Function 48> Gs ( K Pl Ph Fn M (Fn = 48) - Epson TM-T90 Specification

Receipt printer
Hide thumbs Also See for TM-T90:
Table of Contents

Advertisement

Confidential
GS ( K p
p
fn m
L
H
[Name]
Print control method(s)
[Description] • Set the print control specified by fn.
fn
48
GS ( K p
49
GS ( K p
50
GS ( K p
97
GS ( K p
• The density of printing with the four-part energizing on the two-color paper may not be
[Notes]
changed.
• To improve the quality of two-color printing, it is recommended to print with two-part
energizing.
<Function 48> GS ( K p
[Format]
ASCII
Hex
Decimal
× 256) = 2 (p
[Range]
(p
+ p
L
H
fn = 48
1 ≤ m ≤ 4, 49 ≤ m ≤ 52
[Default]
m = 1
[Description] • Selects the print control mode.
m
1, 49
2, 50
3, 51
4, 52
• When (m = 3, 4, 51, or 52), the paper may be fed for the maximum 10 dot lines.
[Note]
EPSON
Format
Function No.
p
fn m
L
H
p
fn m
L
H
p
fn m
L
H
p
fn m
L
H
p
fn m (fn = 48)
L
H
GS
(
K
p
1D
28
4B
p
29
40
75
p
= 2, p
= 0)
L
H
Print control mode
Selects print control mode 1 (standard).
Selects print control mode 2 (fence bar code).
Selects print control mode 3 (ladder bar code).
Selects print control mode 4 (2-dimensional code).
TITLE
TM-T90
Specification
(STANDARD)
48
Specifies the print control mode.
49
Sets the print density.
50
Sets the print speed.
97
Sets the number of parts for energizing the
head.
p
fn
m
L
H
p
fn
m
L
H
p
fn
m
L
H
SHEET
REVISION
Function
NO.
NEXT
SHEET
F
136
135

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents