Confidential
<Function 3> GS ( C p
[Format]
ASCII
Hex
Decimal
× 256) = 3 (p
[Range]
(p
+ p
L
H
m = 0
fn = 3, 51
b = 0
[Description] • Transmits the number of bytes of memory used in the NV user memory.
Header
Identifier
Number of bytes of
memory used
NUL
<Function 4> GS ( C p
[Format]
ASCII
Hex
Decimal
× 256) = 3 (p
[Range]
(p
+ p
L
H
m = 0
fn = 4, 52
b = 0
[Description] • Transmits the number of bytes of remaining memory (unused area) in the NV user memory.
Header
Identifier
Number of bytes of
remaining memory
NUL
EPSON
p
m fn b (fn = 3, 51)
L
H
GS
(
C
p
1D
28
43
p
29
40
67
p
= 3, p
= 0)
L
H
Hexadecimal
37H
28H
30H – 39H
00H
p
m fn b (fn = 4, 52)
L
H
GS
(
C
p
1D
28
43
p
29
40
67
p
= 3, p
= 0)
L
H
Hexadecimal
37H
29H
30H – 39H
00H
TITLE
TM-T90
Specification
(STANDARD)
p
m
fn
L
H
p
m
fn
L
H
p
m
fn
L
H
Decimal
55
40
48 – 57
0
p
m
fn
L
H
p
m
fn
L
H
p
m
fn
L
H
Decimal
55
41
48 – 57
0
SHEET
REVISION
b
b
b
Amount of data
1 byte
1 byte
1 – 6 bytes
1 byte
b
b
b
Amount of data
1 byte
1 byte
1 – 6 bytes
1 byte
NO.
NEXT
SHEET
F
106
105