3
3.5.21
Specifying the default address input screen (mode 366)
Specify the default address input screen for IP address fax transmissions.
Factory settings
Factory settings
Bits
Settings
Specifying the settings
During the production of this unit, the settings in the shaded cells were selected.
Bits
Description
7
-
6
Specify the default address input screen for IP address fax
transmissions.
5-0
-
3.5.22
Specifying settings concerning IP relay operations appearing in the activity report
(mode 368)
Specify whether or not the results of IP relay operations are indicated in the activity report.
Factory settings
Factory settings
Bits
Settings
Specifying the settings
During the production of this unit, the settings in the shaded cells were selected.
Bits
Description
7-1
-
0
Specify whether or not the results of IP relay operations are
indicated in the reception report.
3-32
Specifying machine functions (software switch settings)
7654 3210
0000 1000 (HEX: 08)
7654 3210
1000 0010 (HEX: 82)
Settings
Details
0
*Do not change the setting
for this bit.
0
Gives priority to IP address
input
1
Gives priority to host name
input
001000
*Do not change the settings
for these bits.
Settings
Details
1000001
*Do not change the settings
for these bits.
0
Not indicated
1
Indicated
bizhub C200