Specifying machine functions (software switch settings)
3.5.4
Specifying the storage time for failed transmission originals (mode 004)
Specify the length of time for storing originals that could not be transmitted.
Factory settings
Factory settings
Bits
Settings
Specifying the settings
During the production of this unit, the settings in the shaded cells were selected.
Bits
Description
7-4
-
3-0
Specify the length of time for storing originals that could not
be transmitted in the memory.
bizhub C200
7654 3210
0000 0110 (HEX: 06)
Settings
Details
0000
*Do not change the settings
for these bits.
0000
0 minute
0001
10 minutes
0010
20 minutes
0011
30 minutes
0100
40 minutes
0101
50 minutes
0110
1 hour
0111
2 hours
1000
4 hours
1001
8 hours
1010
12 hours
1011
24 hours
1100
72 hours
Others
*Do not specify any settings
other than those mentioned
above.
3